Fix the serving and water volume
Record the creatine mass, water volume, temperature, pH and mixing time. Prepare a control without creatine using the same vessel and mixing method. Record appearance immediately, after five minutes and at the end of the chosen hold. If the control containing flavor, acid or mineral salts also forms sediment, the residue in the glass cannot all be attributed to creatine.
Purity, water solubility and residue in the glass
Our CreAssure product information lists minimum purity of 99.5% and minimum water solubility of 95%. The first value describes composition and the second reports a solubility test result. The public product sheet omits the concentration, temperature and separation method used in that test. To compare a glass trial with the published value, obtain the method details and quantify creatine in the separated liquid phase.