Powders and formulation

Cleaning the heat-seal area on creatine sachets

Powder scattered during filling can contaminate the sachet sealing surface and reduce seal integrity. Include line cleaning in package checks.

Biontera

Inspect the seal area under magnification

During a production trial, inspect the inside of sachet openings and the seal line under magnification. Match any leaking or weak seals with the machine time. Hold heat, pressure and dwell time constant while changing cleaning intervals to observe the effect.

Measure integrity with a validated test

Use a tensile method suitable for flexible packaging to measure seal separation strength. Whether a pack leaks is a different question and calls for a leak test suited to the package. Compare clean and powder-contaminated seals on both outcomes. A result within the seal-strength range does not establish that the same pack is free of leaks.

Compare creatine ingredients