Creatine ingredients · Physical grade selection

200 mesh creatine monohydrate.

Choose the particle profile that fits your product, from powder-blend texture to capsule filling. We plan 200 mesh creatine monohydrate supply around your purity, sieve-analysis, sample and formulation requirements.

Defined fineness for your production process.

200 mesh is a sieve designation for ingredient fineness. In the US standard sieve series, No. 200 corresponds to a nominal opening of approximately 75 µm. The actual particle profile is defined by the percentage passing that sieve and, where needed, the size distribution.

We clarify the sieve standard and required percentage passing in the purchasing specification. Where needed, the particle-size distribution measured by laser diffraction also forms part of the technical assessment.

Source: AOAC Official Methods of Analysis (2023) — Definition of Terms and Explanatory Notes

Micronized creatine: a physical profile for your formulation.

Micronization allows particle size and shape to be assessed against manufacturing needs. RESS research on creatine monohydrate examined how processing conditions affect these physical properties. The study’s scope is particle characterisation.

We evaluate a finer powder’s mixing, wetting and sensory properties in your own formulation. Flow, dusting and agglomeration also matter to ingredient selection. We use the term “micronized” alongside a measurable particle specification.

Source: Hezave et al. (2010) — Micronization of creatine monohydrate via Rapid Expansion of Supercritical Solution (RESS)

Three complementary measures: purity, dissolution and sieve analysis.

We assess creatine monohydrate content through an appropriate assay and the particle profile through sieving or size analysis. Reading the 200 mesh grade alongside these results defines the technical properties of the ingredient for your formulation.

For dissolution trials, we record the amount used, water volume, temperature, pH and mixing time, allowing samples to be compared under the same conditions. This assesses formulation behaviour; comparisons of bioavailability or required amounts need appropriate research on the relevant ingredient.

What we assess in the technical dossier.

For every ingredient we supply, we verify identity, content and quality characteristics through accredited laboratory testing. When selecting a 200 mesh grade, we match the following information to the product specification and relevant batch CoA.

AreaInformation assessed
Identity and contentCreatine monohydrate definition, method, result and calculation basis
Particle profileSieve standard, percentage passing and available size distribution
ImpuritiesCreatinine, DCD, DHT and other appropriate acceptance criteria
Processing suitabilityFlow, moisture, bulk density and blend uniformity
SupplyLot documentation, packaging, storage conditions and sample scope

Follow the same criteria from powder to finished product.

For sachets and powdered drink blends, we assess serving size, co-ingredients and the liquid volume used during preparation together. Capsule and tablet projects require assessment of fill weight, flow and excipients.

Liquid products require evaluation of pH, packaging and active content during storage, alongside particle fineness. Research on creatine solutions shows why formulation and storage conditions need separate assessment. We therefore verify the shelf-life target through finished-product testing.

Source: Ganguly et al. (2003) — Evaluation of the stability of creatine in solution prepared from effervescent creatine formulations

Start with your technical requirements.

Share the intended dosage form, planned creatine amount, production schedule and estimated annual requirement. We can define the appropriate specification, document scope and sample assessment together, supported by formulation consultancy, analytical planning and submission-dossier preparation.

Common questions

How many microns is 200 mesh?

In the US standard sieve series, No. 200 has a nominal opening of approximately 75 µm. This defines the sieve aperture; the particle profile is completed by the standard used and percentage passing.

How is dissolution assessed for 200 mesh creatine?

We assess dissolution at your intended amount and liquid volume, with defined temperature, pH, time and formulation conditions. This gives you product-specific dissolution information alongside the particle profile.

How are 200 mesh creatine and CreAssure positioned?

200 mesh describes physical fineness, while CreAssure identifies SSV Pharma’s branded ingredient offered through Aquasol™. We assess the physical profile and technology choice through each product’s specification.

What should we review in the batch CoA?

Review product and lot identity, analytical methods, purity and impurity results, sieve-passing criteria, units and document date together.

Related resources

Choose for your formulation.

Let’s develop your next formulation.

Share your product format and annual requirement. Let’s plan the technical documents, samples and supply together.

Discuss your project