Weigh the incoming and outgoing material
In a pilot, pass 1 kg of powder through a specified sieve. Divide the mass collected below the sieve by the input mass to obtain the usable passing fraction. Record oversize material and equipment residue separately. If the masses add up to less than the input, record the difference as unaccounted loss. Allow for weighing uncertainty and repeat the run under the same conditions.
What was retained on the sieve?
Laboratory review should distinguish whether material retained on the sieve is an agglomerate, foreign matter or an expected coarse fraction. Returning it to the main batch automatically may create a quality risk. Sieving does not replace the CoA specification, and “200 mesh” should not be read as a passing percentage. This record informs both equipment capacity and recoverable product per lot, helping guide scale-up.