Testing, sourcing and research

How to adjust a production weigh-in for lot assay

The target on the production order and the percentage on the certificate must refer to the same analyte. Otherwise the arithmetic can be correct and the weighed amount wrong.

Biontera

Chemical basis for the correction

State whether the target is creatine monohydrate or anhydrous creatine equivalent. Use an as-is fraction for the material being weighed. A dry-basis result needs method-compatible correction data before use.

Weighing for a 10 kg target

For 10 kg of creatine monohydrate and a lot assaying at 99.0% monohydrate as supplied, weigh 10 ÷ 0.99 = 10.101 kg of material before the agreed rounding step. A 10 kg target expressed as anhydrous creatine requires a different calculation. Record scale resolution and the approved rounding rule.

Compare creatine ingredients