Biontera · Creatine ingredient supply

CreaStab. Creatine designed for stability.

Microencapsulated creatine monohydrate for formulations where heat and pH matter. For pasteurised beverage, shot and other heat-treated product projects, we assess CreaStab using manufacturer stability data and your actual processing conditions.

A protected ingredient. A process-specific choice.

CreaStab is a Zeus Hygia ingredient produced with microencapsulation technology. Its protective matrix is intended to limit creatine degradation under challenging formulation conditions. The matrix forms part of the ingredient, so the amount of CreaStab used in a formula is calculated from its actual creatine content.

The 2026 test batch had a starting creatine assay of 58.85%. This is distinct from the purity specification of a conventional monohydrate powder. Batch-specific documentation guides formulation calculations.

Comparative ingredient stress tests

Creatine retained after heat and pH exposure.

The manufacturer report compares CreaStab with standard creatine monohydrate under three conditions. The chart expresses each final assay as a percentage of that ingredient’s own starting assay.

Creatine retention: pH 2, CreaStab 96.3%, standard 74.1%; pH 4, 85.4% and 84.2%; heat, 95.8% and 63.6%.
Retention (%) = final assay / initial assay × 100. Rounded to one decimal. Raw values below.
Test conditionCreaStab assay (%)Standard monohydrate assay (%)
pH 2 · 48 hours58.85 → 56.6799.1 → 73.40
pH 4 · 48 hours58.85 → 50.2899.1 → 83.48
135–150°C · 2–5 seconds58.85 → 56.3599.1 → 63.02

Source: Zeus Hygia, CreaStab Stability & Solubility Summary Report, pp. 2–3. Batches CRT-P-005/2026 and C20260329C. These are manufacturer-reported ingredient tests, not a clinical study. The summary does not specify replicate counts, variability or the assay method.

A measured starting point for heat-treated formulations.

The creatine retention reported in the manufacturer’s short high-heat test provides a practical starting point for assessing CreaStab in thermally processed formulations. The reported condition is a UHT-like challenge at 135–150°C for 2–5 seconds. Pasteurisation suitability is established against the actual temperature–time profile of the intended formulation.

For your beverage or shot, we review the pH, temperature–time profile, order of addition, packaging and intended shelf life. A pilot batch should confirm creatine content after processing and during storage. This makes the decision specific to your product.

Powder storage data · Separate test batch

Stability followed over 12 months.

98.2%

Creatine retained after 12 months
25°C · 60 ± 5% RH

99.2%

Creatine retained after 6 months
40°C · 75 ± 5% RH

StorageInitial3 months6 months9 months12 months
25°C · 60 ± 5% RH56.3256.2156.0155.6755.32
40°C · 75 ± 5% RH56.32—55.89——

Technical note: Creatine content is reported as % w/w; the manufacturer specification is not less than 50.0% w/w. Powder batch CRT-P-003/2025. Microbiological results are within the stated limits. Retention values are calculated from the initial and final assays. Finished-beverage shelf life is established through stability testing of its own formulation and packaging.

Lower settling in the reported comparison.

In the reported comparison, 5 g of each ingredient was added to 250 mL water and settling was assessed after 24 hours. CreaStab was reported at 29%, compared with 46% and 54% for the two standard monohydrate samples.

This comparison assesses settling under the stated conditions using equal ingredient masses; active-creatine amounts differ because CreaStab includes a microencapsulation matrix. Equilibrium solubility, clarity and texture are evaluated separately in pilot trials of the final formulation.

Common questions

Which features distinguish CreaStab and CreAssure?

CreaStab is Zeus Hygia’s microencapsulated creatine ingredient developed with a focus on stability. SSV Pharma’s CreAssure focuses on solubility through Aquasol™. The results on this page describe the specified CreaStab test batches.

How can the heat test support pasteurised-product development?

The manufacturer’s 135–150°C, 2–5-second test provides starting data for heat-treated projects. Suitability for your formula’s temperature–time profile, pH and proposed shelf life is established through pilot work and product analysis.

How should 12-month powder stability be assessed?

The study tracks creatine content during storage of the specified powder batch. For beverages, we complement these data with finished-product stability work planned around pH, water activity, heat treatment and packaging.

Explore the range

Let’s develop your next formula.

Share your product format, target market, processing conditions and estimated annual demand. We will plan technical documentation, samples and supply around your project.

Request technical documents