Maintain mass balance across sub-batches
For example, divide a 30 kg formula into three equal pilot blends. Use the same addition order and mixing time and collect a separate sample from each load. Weigh each sub-batch transferred to the combining container. Record powder left on the mixer walls or in the transfer vessel. Compare the mass actually reaching the final container with the formula target.
Sample again after combining
After combining the loads, take separate samples at the beginning, middle and end of discharge. If a result is outside target, examine the sub-batch assays and transfer losses. Link the scale calibration record with the weighings. The trial characterizes production with small mixer loads. If a larger blender is introduced, its fill level and mixing conditions require separate verification.